Skip to content

Settings⁠

PowerOn Pro ships with a number of configurable settings to personalize your VS Code experience as you develop.

Auto Associate PowerOn Workspace⁠

If more than 50% of your active workspace has known PowerOn file extensions, a file association for poweron on the path will be added automatically.

Default Value Available Values
true true or false

Auto Deploy `#INCLUDE` Files⁠

Controls how #INCLUDE files are deployed when deploying a PowerOn (only for non-Remote Syms).

Default Value Available Values
off off, prompt, or silent

Auto Disconnect Sym⁠

Controls when your active Sym connection should automatically disconnect.

Default Value Available Values
never never, 1 hour, 4 hours, 8 hours, or 12 hours

Auto Validate PowerOn⁠

Controls when the language server runs PowerOn validation. Useful if you like to validate your PowerOn file each time you save.

Default Value Available Values
off off or onsave

Batch⁠

Batch related configuration options specific to the SSH connection type.

Fetch Report Timeout (SSH)⁠

The maximum time to wait (min) for the completion of a batch PowerOn run.

Default Value Available Values
15 Between 1 and 60

Queue Override (SSH)⁠

The batch queue number to use when poweronPro.batch.queueSelection is set to override.

Default Value Available Values
0 Between 0 and 3

Queue Selection (SSH)⁠

Controls how the batch queue is selected for a batch PowerOn run. The available options will either use the first available queue, prompt you to select a queue, or use the override value set by the Queue Override setting.

Default Value Available Values
first first, prompt, or override

Report Viewer⁠

Controls where batch reports are displayed.

Default Value Available Values
editor output, editor, or poweron-pro

CLI Worker Timeout⁠

The maximum time (sec) to wait for the initialization of the Symitar CLI workers which is only used with an SSH connection type to Symitar.

Default Value Available Values
30 Between 5 and 120 seconds

Debug⁠

Enables debug logging for the @libum-llc/symitar library. The logs will appear in the PowerOn Pro output channel.

Default Value Available Values
false true or false

Diagnostics⁠

Real-time diagnostics configuration options which are triggered when the PowerOn changes in an active text editor.

Data Types⁠

Plus Shows incorrect variable assignments and invalid data type declarations as errors for PowerOn files.

Default Value Available Values
false true or false

Constant Reassignment⁠

Plus Warns when a constant is reassigned in PowerOn files.

Default Value Available Values
true true or false

Defined Variables⁠

Plus Shows undefined variables or procedures as errors for PowerOn files.

Default Value Available Values
true true or false

Expression Validation⁠

Plus Validates operator and operand type compatibility in expressions for PowerOn files.

Default Value Available Values
true true or false

Field Validation⁠

Plus Validates field mnemonics against their record types. For example, using a SHARE field mnemonic in a context that expects an ACCOUNT field will be flagged as an error.

Default Value Available Values
true true or false

Function Validation⁠

Plus Validates function names and parameter counts. Unknown function names and incorrect numbers of arguments will be flagged as errors.

Default Value Available Values
true true or false

Statement Validation⁠

Plus Validates FMPERFORM and TRANPERFORM statements, including record type compatibility, allowed operations, TARGETFILE keyword usage, and transaction codes.

Default Value Available Values
true true or false

Syntax Errors⁠

Plus Shows syntax errors detected by the PowerOn parser and analyzer. These are structural issues in your PowerOn code such as missing keywords, unexpected tokens, malformed statements, mismatched DO / END blocks, or unsupported record and field references.

Default Value Available Values
true true or false

Unused Variables⁠

Plus Shows unused variables as dimmed for PowerOn files.

Default Value Available Values
true true or false

CodeLens References⁠

Plus Shows an N references CodeLens above defined variables and procedures.

Default Value Available Values
true true or false

Formatter⁠

Configuration options for the PowerOn code formatter.

Align Defines⁠

Align = signs in DEFINE sections for table-like readability.

Default Value Available Values
false true or false

Align Logical Operators⁠

Align logical operators (AND, OR) vertically at the end of each line in multi-line conditions. Forces line breaks at each operator.

Default Value Available Values
false true or false

Expand Parentheses⁠

Expand parenthesized expressions onto multiple lines with opening/closing parentheses on their own lines and content indented.

Default Value Available Values
false true or false

Format On Save⁠

Automatically format PowerOn files when saving.

Default Value Available Values
false true or false

Indent Size⁠

Number of spaces per indentation level (or tab width when useTabs is enabled).

Default Value Available Values
1 Between 0 and 8

Keyword Case⁠

Casing for PowerOn keywords, database records, and fields (e.g., TARGET, ACCOUNT, CLOSEDATE).

Default Value Available Values
upper upper, lower, or preserve

Max Blank Lines⁠

Maximum consecutive blank lines to preserve within divisions.

Default Value Available Values
1 Between 1 and 3

Maximum line length for PowerOn code before wrapping.

Default Value Available Values
80 Between 40 and 200

Section Spacing⁠

Number of blank lines between major divisions (TARGET, DEFINE, SETUP, SELECT, SORT, PRINT, TOTAL, PROCEDURE).

Default Value Available Values
1 Between 0 and 5

Space After Delimiter⁠

Add space after comma delimiters in function parameters (e.g., FUNC(a, b) vs FUNC(a,b)).

Default Value Available Values
false true or false

Space Around Operators⁠

Add spaces around all operators: assignment (=), arithmetic (+, -, *, /), and comparison (<>, <, >, <=, >=). Logical operators (AND, OR, WITH) always have spaces.

Default Value Available Values
false true or false

Space Around Operators Exclude⁠

Comma-separated list of statement types to exclude from space-around-operators formatting for the = operator (e.g., COL,DATASIZE).

Default Value Available Values
-- Comma-separated list of statement types

Use Tabs⁠

Use tabs instead of spaces for indentation.

Default Value Available Values
false true or false

Uppercase Identifiers⁠

Uppercase all identifiers (variable names, procedure names). PowerOn is case-insensitive; some shops prefer all-caps for mainframe consistency.

Default Value Available Values
false true or false

Include Paths⁠

Additional absolute directory paths to search for #INCLUDE files. These directories will be searched in addition to the directory of the PowerOn file being processed.

Default Value Available Values
[] List of any local directory paths

Local Symitar Path⁠

Plus The root path where your local Sym directories are synchronized. This is a required field for the Remote Syms feature and it's recommended to set as a path not directly in a typical folder structure for projects.

Default Value Available Values
-- Any local directory path

Offline Validation⁠

Controls whether a randomly named PowerOn is created, uploaded for validation, then deleted.

Default Value Available Values
true true or false

Preferred Case⁠

Controls the case of keywords, functions, variables, and records. Additionally, you'll see this reflected in other relevant areas such as hovers and snippets.

Default Value Available Values
upper upper, lower, or camel

Semantic Tokens⁠

Plus Enables analyzer-driven semantic syntax highlighting with distinct tokens for variables, records, fields, procedures, constants, and literals.

Default Value Available Values
true true or false

Remote Sym SFTP Concurrency⁠

Plus The number of files to download simultaneously when using SFTP sync (used by Remote Syms and Reports).

Default Value Available Values
20 Between 1 and 50

Remote Sym Sync Method⁠

Plus Controls how Remote Syms are synchronized with the Symitar server.

Default Value Available Values
sftp sftp or rsync
  • sftp: Use SFTP for synchronization (no external dependencies required)
  • rsync: Use rsync for synchronization (requires WSL on Windows, rsync and sshpass installed)

Reports⁠

Configuration options for the Symitar Explorer Reports feature.

Background Sync Interval⁠

Plus Background sync interval in minutes for reports. Set to 0 to disable background syncing.

Default Value Available Values
5 Between 0 and 60

Retention Days⁠

Plus Number of days of reports to keep locally synced.

Default Value Available Values
15 Between 1 and 360

SSH Port⁠

The port to use when connecting to the Symitar host. For almost all cases this should be 22 but if you have port-forwarded and need the flexibility to use SSH over a different port, this is how you'd do it.

Default Value Available Values
22 Any available port